BioClean
In today’s technologically demanding environment, a micro-particle can cause a great deal of trouble. For instance, a speck of dust or an airborne micro-organism could cause a risk to patient safety in a hospital or security risk at a data center. Everest Bioclean is a complete, maintenance-free ceiling solution for cleanroom applications. Along with its incredible, antimicrobial performance, it is an ideal product for critical spaces where bacterial, mold, fungal, or microbial activities are evident. With the strength of fiber cement as its base material, Bioclean shows superior performance in comparison to mineral fibre, calcium silicate or any other cleanroom ceilings. Get the ultimate peace of mind with BioClean ceiling solution for industries like healthcare, pharmaceutical, IT, and bio-labs with the strength of fibre cement.
Solutions
Features

Anti-Microbial
99.9% microbe kill rate in 24 hours

ISO 4 Certified
Class 10 ensuring lesser particulate emission

Light Reflectance
Brighter space, >93% light reflectance

Humidity Resistance
99%RH

Sag Resistant
Doesn't sag even in moist conditions

Low Maintenence
10 years warranty on anti-sagging and anti-microbial property


Product Specifications


Description | Unit | Standard | Bioclean |
Product Dimensions | mm | 595 X 595 in 6mm thickness | |
Type | IS 14862:2000 | A | |
Category | IS 14862:2000 | 3 | |
Microbe Kill Rate | Upto 99.9% in 24 hours | ||
ISO | 4 (Class 10) | ||
Light Reflectance | % | >93 | |
Sag resistant | +/- 1mm deflection per tile from normal at equilibrium | ||
Humidity Resistance | 99%RH | ||
Modulus of Rupture (dry) | MPa | ASTM C 1185 | >10 |
Thermal Conductivity at 50°C (Mean Temperature) | W/mk | ASTM C 518 | 0.2 |
Fire Resistance Properties | ||
Reaction to Fire | EN 13501: Part-1 | A2-s1-d0* |
*Non Combustible with no smoke and no fire droplets |
Check out how we have
Re-imagined spaces with our BioClean Ceiling
Explore
Product Resources
FAQ’S
What is the difference between ISO 4 and ISO 5?
ISO 4 is the tag of clean room certification. There are many classes under this, mainly Class 10, Class 100, Class 1000. This mainly refers to the particulate emission. Class 10 means 10 times lesser paiculate emission than Class 100. Other cleanroom ceiling solutions fall under ISO 5 (Class 100).
Is the usage of Bioclean restricted to only Hospitals and Laboratories?
Bioclean as a product can be used not just in hospitals and laboratories, it’s usage can be extended to any space where you require cleanroom application. Its anti-microbial properties make it ideal for data centres, server rooms, food industry, manufacturing units.
Is Bioclean installation any different from conventional grid ceiling installation?
Bioclean installation remains the same as conventional grid ceiling installation.
Can Bioclean tiles be painted?
No. It should not be painted